INSTALLATION
DIMENSIONS DU LOCAL TECHNIQUE
LA FIGURE 3 INDIQUE LES DIMENSIONS RECOMMANDÉES POUR UNE INSTALLATION INTÉRIEURE DANS UN LOCAL TECHNIQUE. UN DÉGAGEMENT MINIMUM DE 8 CM SUR LES TROIS CÔTÉS DE L’APPAREIL DOIT PERMETTRE LA CIRCULATION DE L’AIR REPRIS AINSI QU’UN ACCÈS POUR LES TRAVAUX D’INSTALLATION ET D’ENTRETIEN. LES FIGURES 3 ET 4 INDIQUENT LES DIMENSIONS DE RÉFÉRENCE ET LES DÉGAGEMENTS.
FIGURE 3
LOCAL TECHNIQUE
BOÎTIER INSTALLÉ DANS LE LOCAL, AVEC
PLATEFORME OPTIONNELLE
FILTRE 25’’ X 20’’
(FOURNI SUR PLACE)
BRANCHEMENTS ÉLECTRIQUES
|
| RACCORDEMENT | |
|
| THERMOSTAT | |
| PANNEAU D’ACCÈS VPRG4 AVEC | ||
| GRILLE DE REPRISE D’AIR |
| |
|
| INTERRUPTEUR | |
|
| BAC D’ÉGOUTTEMENT | |
|
| INSTALLÉ SUR PLACE | |
• | DIMENSIONS DU BOÎTIER DU |
| |
| L58,7 CM X P 58,7 CM X H 81,9 CM. |
| |
• | OUVERTURE POUR LE PLÉNUM MURAL : |
| |
| L62,5 CM X H 78,4 CM. | PLATEFORME | |
• | OUVERTURE POUR LA PORTE D’ACCÈS : | ||
OPTIONNELLE | |||
| L 68,6 CM X H 141,6 CM. | ||
|
|
•VOIR PAGE 11, FIGURE 13 POUR L’INSTALLATION DE L’APPAREIL.
CONDUIT D’AIR RIGIDE
MUR EXTÉRIEUR
CONDUIT D’AIR FLEXIBLE
PLÉNUM MURAL
SÉPARATEUR DE PLÉNUM
RACCORD DE DRAIN 3/4’’ FEM.
BOÎTIER INSTALLÉ À 6 CM À
L’INTÉRIEUR DU PLÉNUM
DÉGAGEMENT MINIMUM DE 8 CM SUR LES 3 CÔTÉS POUR L’INSTALLATION ET L’ENTRETIEN
FIGURE 4
29,9 CM
VUE DE DESSUS
17,7 CM
MUR
EXTÉRIEUR
15,2 CM
5,1 CM
45