CARACTÉRISTIQUES ÉLECTRIQUES
|
|
| VHA09K |
|
|
| VHA12K |
|
|
| VHA18K |
| |
WATTS CHAUFFE | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 |
| 3400/2780 |
| 5000/4090 | ||
TENSION |
| 230/208 |
|
|
| 230/208 |
|
|
| 208/230 |
|
| |
BTU/H CHAUFFAGE | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 |
| 11600/9500 | 17000/13900 | |||
AMPÈRES CHAUFFAGE | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 |
| 14.8/13.4 |
| 21.7/19.7 | ||
COURANT MIN. ADMISSIBLE | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 | 15 |
| 19.9 |
| 28.6 | ||
DISJONCTEUR DIVIS. (A) | 15 | 20 | 30 | 15 | 20 | 30 | 15 |
| 20 |
| 30 | ||
COMPR. ROTOR BLOQUÉ (A) | 18.5 | 18.5 | 18.5 | 26 | 26 | 26 | 42 |
| 42 |
| 42 | ||
AMPÈRES CLIMATISATION | 4.1/4.3 | 4.1/4.3 | 4.1/4.3 | 5.3/5.5 | 5.3/5.5 | 5.3/5.5 | 8.2/8.6 |
| 8.2/8.6 |
| 8.2/8.6 | ||
PUISSANCE CHAUFFAGE STD | 2.5 KW |
| 3.4 KW |
| 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW | ||
CONNEXION AU SECTEUR | RACCORDEMENT FIXE |
|
| RACCORDEMENT FIXE |
| RACCORDEMENT FIXE |
| ||||||
RECOMMENDED BRANCH |
|
|
|
|
|
|
|
|
|
|
|
|
|
CIRCUIT WIRE SIZES | 14 |
| 12 |
| 10 | 14 | 12 | 10 | 14 |
| 12 |
| 10 |
* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ALIMENTATION ÉLECTRIQUE
Calibre des fils | UTILISEZ UNIQUEMENT LES CALIBRES DE FILS | |
RECOMMANDÉS POUR LES CIRCUITS À PRISE SIMPLE. | ||
| ||
|
| |
| UTILISEZ UNIQUEMENT UN FUSIBLE OU UN DISJONC- | |
Fusible/disjoncteur | TEUR HACR DU TYPE ET DE LA PUISSANCE SPÉCIFIÉS SUR | |
LA PLAQUE SIGNALÉTIQUE DE L’APPAREIL (VOIR EXEMPLE | ||
| ||
| ||
| L’INSTALLATION D’UNE PROTECTION ADÉQUATE CONTRE LES | |
| SURINTENSITÉS. | |
| L’APPAREIL DOIT ÊTRE RELIÉ À LA TERRE PAR LE | |
Mise à la terre | CIRCUIT DIVISIONNAIRE OU AU MOYEN DU FIL DE | |
MISE À LA TERRE FOURNI POUR LES INSTALLATIONS À | ||
| ||
| BRANCHEMENT PERMANENT. S’ASSURER QUE LE | |
| CIRCUIT DIVISIONNAIRE OU LA PRISE ÉLECTRIQUE | |
| EST RELIÉ À LA TERRE. | |
|
| |
| EMPLOYEZ LES CALIBRES DE FILS INDIQUÉS DANS LES | |
Sélection du | TABLEAUX ET INSTALLEZ UN CIRCUIT DIVISIONNAIRE UNIQUE. | |
TOUT LE CÂBLAGE DOIT ÊTRE CONFORME AU CODE DE | ||
calibre des fils | ||
L’ÉLECTRICITÉ ET AUX RÉGLEMENTATIONS LOCALES. | ||
| ||
| NOTE : N’UTILISEZ QUE DES CONDUCTEURS EN CUIVRES. | |
|
|
NOTE : TOUS LES CÂBLAGES EFFECTUÉS SUR PLACE DOIVENT ÊTRE CONFORMES AUX EXIGENCES DU CODE CANADIEN DE L’ÉLECTRICITÉ ET AUX RÉGLEMENTATIONS LOCALES. IL INCOMBE À L’INSTALLATEUR DE S’ASSURER DE LA CONFORMITÉ DU CÂBLAGE.
CALIBRE DES FILS ÉLECTRIQUESNOTE : UTILISEZ UNIQUEMENT DES CONDUCTEURS EN CUIVRE. CES CALIBRES SONT RECOMMANDÉS PAR LE CODE CANADIEN DE L’ÉLECTRICITÉ. POUR LES INSTALLATIONS DANS D’AUTRES PAYS,
FILS RECOMMANDÉS POUR UN CIRCUIT DIVISIONNAIRE *
|
|
|
|
|
|
|
|
|
|
|
|
15A | 14 | ||||
20A | 12 | ||||
30A | 10 |
AWG : AMERICAN WIRE GAUGE
*CIRCUIT UNIQUE DEPUIS LE TABLEAU PRINCIPAL.
**POUR UN MAXIMUM DE 30 M DE FIL DE CUIVRE, UN SEUL CONDUCTEUR ISOLÉ, À 60 °C.
AVERTISSEMENT
Risque de choc électrique
COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT UNE RÉPARA-
TION OU UNE INSTALLATION.
L’APPAREIL DOIT ÊTRE CONVENABLEMENT MIS À LA TERRE.
IL DOIT ÊTRE MUNI D’UN FUSIBLE OU D’UN DISJONCTEUR
ADÉQUAT. SON CÂBLAGE D’ALIMENTATION DOIT ÊTRE
CORRECTEMENT CALIBRÉ.
TOUS LES BRANCHEMENTS ET LE CÂBLAGE DOIVENT ÊTRE
EFFECTUÉS PAR UN ÉLECTRICIEN QUALIFIÉ ET DOIVENT ÊTRE
CONFORMES AU CODE CANADIEN DE L’ÉLECTRICITÉ AINSI
QU’À TOUS LES RÈGLEMENTS LOCAUX EN VIGUEUR.
TOUTE IGNORANCE DE CES RECOMMANDATIONS PEUT
CAUSER DES DOMMAGES MATÉRIELS ET DES BLESSURES
GRAVES OU FATALES.
EXEMPLE DE PLAQUE SIGNALÉTIQUE |
120524 |
COOLING EQUIPMENT |
FOLLOWING ITEMS |
OUTDOOR GRILLE |
INDOOR GRILLE |
43