ELECTRICAL DATA
|
| VHA09K |
|
| VHA12K |
|
| VHA18K |
|
HEATER WATTS | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 |
VOLTAGE |
| 230/208 |
|
| 230/208 |
|
| 208/230 |
|
HEATING BTU/H | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 |
HEATING CURRENT (AMPS) | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 |
MINIMUM CIRCUIT AMPACITY | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 |
BRANCH CIRCUIT FUSE (AMPS) | 15 | 20 | 30 | 15 | 20 | 30 | 15 | 20 | 30 |
LRA - COMPRESSOR (AMPS) | 18.5 | 18.5 | 18.5 | 26 | 26 | 26 | 42 | 42 | 42 |
COOLING CURRENT (AMPS) | 4.1/4.3 | 4.1/4.3 | 4.1/4.3 | 5.3/5.5 | 5.3/5.5 | 5.3/5.5 | 8.2/8.6 | 8.2/8.6 | 8.2/8.6 |
BASIC HEATER SIZE | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW |
POWER CONNECTION |
| HARD WIRED |
|
| HARD WIRED |
|
| HARD WIRED |
|
|
|
|
|
|
|
|
|
|
|
RECOMMENDED BRANCH |
|
|
|
|
|
|
|
|
|
CIRCUIT WIRE SIZES | 14 | 12 | 10 | 14 | 12 | 10 | 14 | 12 | 10 |
* |
|
|
|
|
|
|
|
|
|
ELECTRICAL REQUIREMENTS
Wire Size | USE ONLY WIRE SIZE RECOMMENDED FOR | |
SINGLE OUTLET BRANCH CIRCUIT. | ||
| ||
|
| |
| USE ONLY TYPE AND SIZE FUSE OR HACR | |
| CIRCUIT BREAKER INDICATED ON UNIT’S RATING | |
| PLATE (SEE SAMPLE BELOW). PROPER OVER | |
| CURRENT PROTECTION TO THE UNITS IS THE RESPON- | |
| SIBILITY OF THE OWNER. | |
|
| |
| UNIT MUST BE GROUNDED FROM BRANCH CIRCUIT | |
| TO UNIT, OR THROUGH SEPARATE GROUND WIRE | |
| PROVIDED ON PERMANENTLY CONNECTED UNITS. | |
| BE SURE THAT BRANCH CIRCUIT OR GENERAL | |
| PURPOSE OUTLET IS GROUNDED. | |
|
| |
| USE RECOMMENDED WIRE SIZE GIVEN IN TABLES | |
| AND INSTALL A SINGLE BRANCH CIRCUIT. ALL WIRING | |
| MUST COMPLY WITH LOCAL AND NATIONAL CODES. | |
| NOTE: USE COPPER CONDUCTORS ONLY. | |
|
|
NOTE: ALL FIELD WIRING MUST COMPLY WITH NEC AND LOCAL CODES. IT IS THE RESPONSABILITY OF THE INSTALLER TO INSURE THAT THE ELECTRICAL CODES ARE MET.
ELECTRICAL RATING TABLE
NOTE: USE COPPER CONDUCTORS ONLY. WIRE SIZES ARE PER NEC. CHECK LOCAL CODES FOR OVERSEAS APPLICATIONS.
RECOMMENDED BRANCH CIRCUIT WIRE SIZES*
NAMEPLATE MAXIMUM CIRCUIT BREAKER SIZE | AWG WIRE SIZE** |
15A | 14 |
20A | 12 |
30A | 10 |
AWG --- AMERICAN WIRE GAUGE
*SINGLE CIRCUIT FROM MAIN BOX.
**BASED ON 100’ OR LESS OF COPPER, SINGLE INSULATED CONDUCTOR AT 60° C
WARNING
Electrical shock hazard.
TURN OFF ELECTRIC POWER BEFORE SERVICE
OR INTALLATION.
UNIT MUST BE PROPERLY GROUNDED.
UNIT MUST HAVE CORRECT FUSE OR CIRCUIT
BREAKER PROTECTION.
UNIT’S SUPPLY CIRCUIT MUST HAVE THE
CORRECT WIRE CONDUCTOR SIZE.
ALL ELECTRICAL CONNECTIONS AND WIRING MUST
BE INSTALLED BY A QUALIFIED ELECTRICIAN AND
CONFORM TO THE NATIONAL ELECTRICAL CODE
AND ALL LOCAL CODES WHICH HAVE JURISDICTION.
FAILURE TO DO SO CAN RESULT IN PROPERTY
DAMAGE, PERSONAL INJURY AND/OR DEATH.