ELECTRICAL REQUIREMENTS

ELECTRICAL DATA

 

 

VHA09K

 

 

VHA12K

 

 

VHA18K

 

HEATER WATTS

2500/2050

3400/2780

5000/4090

2500/2050

3400/2780

5000/4090

2500/2050

3400/2780

5000/4090

VOLTAGE

 

230/208

 

 

230/208

 

 

208/230

 

HEATING BTU/H

8500/7000

11600/9500

17000/13900

8500/7000

11600/9500

17000/13900

8500/7000

11600/9500

17000/13900

HEATING CURRENT (AMPS)

10.9/9.9

14.8/13.4

21.7/19.7

10.9/9.9

14.8/13.4

21.7/19.7

10.9/9.9

14.8/13.4

21.7/19.7

MINIMUM CIRCUIT AMPACITY

15

19.9

28.6

15

19.9

28.6

15

19.9

28.6

BRANCH CIRCUIT FUSE (AMPS)

15

20

30

15

20

30

15

20

30

LRA - COMPRESSOR (AMPS)

18.5

18.5

18.5

26

26

26

42

42

42

COOLING CURRENT (AMPS)

4.1/4.3

4.1/4.3

4.1/4.3

5.3/5.5

5.3/5.5

5.3/5.5

8.2/8.6

8.2/8.6

8.2/8.6

BASIC HEATER SIZE

2.5 KW

3.4 KW

5.0 KW

2.5 KW

3.4 KW

5.0 KW

2.5 KW

3.4 KW

5.0 KW

POWER CONNECTION

 

HARD WIRED

 

 

HARD WIRED

 

 

HARD WIRED

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED BRANCH

 

 

 

 

 

 

 

 

 

CIRCUIT WIRE SIZES

14

12

10

14

12

10

14

12

10

* AWG-AMERICAN WIRE GAUGE

 

 

 

 

 

 

 

 

 

ELECTRICAL REQUIREMENTS

Wire Size

USE ONLY WIRE SIZE RECOMMENDED FOR

SINGLE OUTLET BRANCH CIRCUIT.

 

 

 

 

USE ONLY TYPE AND SIZE FUSE OR HACR

 

CIRCUIT BREAKER INDICATED ON UNIT’S RATING

 

PLATE (SEE SAMPLE BELOW). PROPER OVER

 

CURRENT PROTECTION TO THE UNITS IS THE RESPON-

 

SIBILITY OF THE OWNER.

 

 

 

UNIT MUST BE GROUNDED FROM BRANCH CIRCUIT

 

TO UNIT, OR THROUGH SEPARATE GROUND WIRE

 

PROVIDED ON PERMANENTLY CONNECTED UNITS.

 

BE SURE THAT BRANCH CIRCUIT OR GENERAL

 

PURPOSE OUTLET IS GROUNDED.

 

 

 

USE RECOMMENDED WIRE SIZE GIVEN IN TABLES

 

AND INSTALL A SINGLE BRANCH CIRCUIT. ALL WIRING

 

MUST COMPLY WITH LOCAL AND NATIONAL CODES.

 

NOTE: USE COPPER CONDUCTORS ONLY.

 

 

NOTE: ALL FIELD WIRING MUST COMPLY WITH NEC AND LOCAL CODES. IT IS THE RESPONSABILITY OF THE INSTALLER TO INSURE THAT THE ELECTRICAL CODES ARE MET.

ELECTRICAL RATING TABLE

NOTE: USE COPPER CONDUCTORS ONLY. WIRE SIZES ARE PER NEC. CHECK LOCAL CODES FOR OVERSEAS APPLICATIONS.

RECOMMENDED BRANCH CIRCUIT WIRE SIZES*

NAMEPLATE MAXIMUM CIRCUIT BREAKER SIZE

AWG WIRE SIZE**

15A

14

20A

12

30A

10

AWG --- AMERICAN WIRE GAUGE

*SINGLE CIRCUIT FROM MAIN BOX.

**BASED ON 100’ OR LESS OF COPPER, SINGLE INSULATED CONDUCTOR AT 60° C

ELECTRICAL RATING TABLE WARNING

Electrical shock hazard.

TURN OFF ELECTRIC POWER BEFORE SERVICE

OR INTALLATION.

UNIT MUST BE PROPERLY GROUNDED.

UNIT MUST HAVE CORRECT FUSE OR CIRCUIT

BREAKER PROTECTION.

UNIT’S SUPPLY CIRCUIT MUST HAVE THE

CORRECT WIRE CONDUCTOR SIZE.

ALL ELECTRICAL CONNECTIONS AND WIRING MUST

BE INSTALLED BY A QUALIFIED ELECTRICIAN AND

CONFORM TO THE NATIONAL ELECTRICAL CODE

AND ALL LOCAL CODES WHICH HAVE JURISDICTION.

FAILURE TO DO SO CAN RESULT IN PROPERTY

DAMAGE, PERSONAL INJURY AND/OR DEATH.

SAMPLE NAMEPLATE