1.4.4 Replacing the Temperature Probe
CAUTION Drain the frypot before pro- ceeding.
CAUTION Drain the frypot before pro- ceeding.

1.4.4 Replacing the Temperature Probe

1. Disconnect the fryer from the electrical supply.

2. Drain the frypot.

3.Remove the controller or computer according to the instructions in Section 1.4.1.

4.Unplug the 12-pin wiring harness from the front of the interface board.

5.Use a pin-pusher to remove the temperature probe wires (pins 1 and 2) from the 12-pin wiring harness

6.Unscrew the temperature probe from the frypot and remove.

7.Apply Loctite™ PST56765 thread sealant or equivalent to threads of the replacement probe.

8.Screw the new probe into the frypot.

9.Reverse Steps 1-5 to reassemble.

10.Check the probe according to the instructions in Section 1.3.6.

1.4.5 Replacing the High-Limit Thermostat in Fryers with Thermostat Controls

1. Disconnect the fryer from the electrical supply.

2. Drain the frypot.

3.Remove the thermostat knob and/or control panel as instructed in Section 1.4.2 or 1.4.3.

4.Disconnect the high-limit thermostat leads from the gas valve pilot coil.

5.Unscrew the high-limit thermostat from the fryer and remove.

6.Apply Loctite™ PST56765 thread sealant or equivalent to the threads of the replacement high-limit thermostat.

7.Reverse Steps 1-5 to the install replacement high-limit.

1.4.6 Replacing the High-Limit Thermostat in Fryers with Other Controls

1.Disconnect the fryer from the electrical supply.

2.Drain the frypot.

CAUTION Drain the frypot before pro- ceeding.CAUTION Drain the frypot before pro- ceeding.

3.Remove the bezel and controller as instructed in Section 1.4.1, Steps 2 and 3.

4.Unplug the 15-pin wiring harness and grounding wire from the controller.

5.Remove the high-limit thermostat wires from the gas valve pilot coil.

1-9