1.4.11 Replacing the Pilot Assembly or Thermopile

4.Remove the high-limit thermostat wire from the gas valve pilot coil.

5.Disconnect the pilot gas line fitting from the gas valve.

6.Disconnect both pipe union collars from the gas valve and remove the valve.

7.Remove the pipefittings from the old gas valve and install them on the replacement valve. Use Loctite™ PST56765 or equivalent pipe thread sealant on the threads.

8.Reverse Steps 1-6 to install the replacement gas valve.

 

WARNING

1.4.11 Replacing the Pilot Assembly or Thermopile

Drain the frypot or remove the

 

handle from the drain valve

1. Remove the burner assembly in accordance with Steps 1-10

before proceeding further.

in Section 1.4.9.

 

2.To replace only the thermopile:

a.Bend the clip at the bottom of the pilot assembly and press the thermopile out of the pilot assembly from the top.

b.Disconnect the thermopile fitting from the gas valve pilot coil.

c.Reverse Steps a and b to install the replacement thermopile.

3. To replace the complete pilot assembly:

Bend the clip to release the thermopile.

a.Disconnect the pilot tubing from the bottom of the pilot assembly.

b.Remove the screw from the pilot mounting bracket to release the pilot assembly.

c.Disconnect the thermopile fitting from the gas valve pilot coil.

d.Reverse Steps a-c to install the replacement assembly.

4. Reinstall the burner assembly by reversing Steps 1-8 of Section 1.4.9.

1.4.12 Replacing the Frypot

1.Drain the frypot.

2.Disconnect the fryer from the electrical power supply. Turn off the gas supply and disconnect the fryer.

3.Remove all accessories (i.e., frypot covers, basket lift arms, etc.) from the fryer.

4.If the fryer is equipped with a thermostat control, remove the thermostat knob and control panel according to Steps 3-8 in Section 1.4.3.

NOTE: If the fryer is configured with a melt cycle, the thermostat leads will be connected to the PC board rather than to the terminal block and gas valve. Disconnect the leads from the PC board if this is the case.

1-12