4.11 Filter Menu

The computer displays CLOSE DISPOSE VALVE.

11.Close the dispose valve by pushing the valve handle toward the rear of the fryer until it stops. Relock the valve if required by your manager.

The vat is ready to be refilled with oil. Continue to Section 4.10.4.4 to fill the vat, otherwise press the (2) button to exit.

*NOTE: If the computer displays RTI TANK FULL alternating with CONFIRM press the (1) button and call the bulk oil waste provider. The display returns to OFF.

4.10.4.4 Refilling the Vat from Bulk Oil Systems after Disposal

The computer displays fill pot from bulk? alternating with yeS NO.

The bulk oil refill pump uses a momentary switch. It only pumps when the switch is depressed.

1.

Press and hold the (1 yes) button to refill the vat

 

until the oil reaches the lower fill line.

2.

With the vat full, release the (1 yes) button.

3.Press the (2) button, when the vat is full, to close the fill valve. The computer displays off.

4.11 Filter Menu

The filter menu selections are used for filtering, draining, filling and disposing.

4.11.1 Accessing the Filter Menu

1. Press and hold the filter button for the selected vat for three seconds.

The computer displays filter menu for three seconds, changing to MAINT Filter.

2. Press the t and u buttons to scroll between:

a. auto filter

See pg. 5-2

b. maint filter

See pg. 5-8

c. dispose

See pg. 4-16

d. drain to pan

See pg. 4-20

e. fill VAT from DRAIN pan

See pg. 4-21

f. fill VAT from bulk

See pg. 4-22

g. PAN TO WASTE

See pg. 4-23

4-19