4.12.3 HIGH-LIMIT TEST MODE

18.Bulk or JIB System: The computer displays SCRUB VAT COMPLETE? alternating with yes. Press the 9 (1 yes) button.

19.Bulk or JIB System: The computer displays DRAINING. The drain opens to drain the small amount of residual solution left in the vat. Rinse excess solution from vat.

20.Bulk or JIB System: The computer displays Rinse complete?

alternating with yes. Press the 9 (1 yes) button to continue when the vat is completely rinsed.

21.Bulk or JIB System: The computer displays REMOVE PAN. Remove the filter pan.

22.Bulk or JIB System: The computer displays VAT and pan DRY?, alternating with yes. Ensure the vat and pan are completely dry.

Manual background DANGER

Ensure that the frypot and filter pan are completely dry and free of water before filling with oil. Failure to do so will cause splattering of hot liquid when the oil is heated to cooking temperature.

23.Bulk or JIB System: The computer displays INSERT pan. Reinstall screen, filter pad, hold down ring and crumb basket removed in step 16. Insert the filter pan.

24.JIB system: The computer displays MANUAL FILL alternating with

yes. Press the 9 (1 yes) button and display returns to OFF.

Bulk system: Go to Section 4.11.4 Fill Vat From Bulk on page 4-22 and begin after step 3.

4.12.3 HIGH-LIMIT TEST MODE

The high-limit test mode is used to test the high limit circuit. The high-limit test will destroy the oil. It should only be performed with old oil. Shut the fryer off and call for service immediately if the temperature reaches 460°F (238°C) without the second high-limit tripping and the computer displays high LIMIT FAILURE alternating with DISCONNECT POWER with an alert tone during testing.

The test is cancelled at any time by turning the fryer off. When the fryer is turned back on, it returns to the operating mode and displays the product.

1. Perform steps 1-3 on pages 4-23 through 4-24.

Computer displays hi limit test.

2. Press the 9 (1 yes) button to continue the high-limit test.

The computer displays hi-limit?alternating with yes no.

3.Press the 9 (1 yes) button to continue the test. If performing the test on a split vat press the 9 (1 yes) button on the side which corresponds to the vat.

The computer displays press and h0ld check.

4. Press and hold the 9 (1 yes) button to initiate the high-limit test.

4-28

Page 46
Image 46
Frymaster BIELA14 warranty High-Limittest Mode, Danger