5.4.4 Filter Error Flowchart
This chart follows the process of clearing a filtration issue. The prompt is displayed when any of the following occur:
1. a clogged filter pad,
2. a tripped or defective filter pump,
3. a leaky
4. a failed drain valve/actuator, or
5. a failed return valve/actuator.
If the computer displays SERVICE REQUIRED, the fryer can be used in most cases by answering NO when the
prompt for SYSTEM ERROR
FIXED? YES NO is displayed. The message repeats every 15 minutes until the issue is repaired and fryer reset by a technician.