
2.1.3 Australian Requirements
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.
2.2Power Requirements
The three phase supply plug for the elements is rated at 60 amps, 250 VAC and is NEMA configuration
|
| WIRE | MIN. | AWG |
| AMPS PER LEG |
| ||
VOLTAGE | PHASE | SERVICE | SIZE | (mm2) | L1 |
| L2 |
| L3 |
208 | 3 | 3 | 6 | (16) | 39 |
| 39 |
| 39 |
240 | 3 | 3 | 6 | (16) | 34 |
| 34 |
| 34 |
480 | 3 | 3 | 8 | (10) | 17 |
| 17 |
| 17 |
220/380 | 3 | 4 | 6 | (16) | 21 |
| 21 |
| 21 |
240/415 | 3 | 4 | 6 | (16) | 20 |
| 20 |
| 21 |
230/400 | 3 | 4 | 6 | (16) | 21 |
| 21 |
| 21 |
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).
DANGER
This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.
DANGER
All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.
2.3After Fryers Are Positioned At the Frying Station
DANGER
No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline at
1.Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both
To level fryers, adjust the casters being careful to ensure the fryer(s) are at the proper height in the frying station.