7.2.5 Bulk Oil System Problems
Problem | Probable Causes |
| A. | Incorrect setup procedure. |
JIB won’t fill. | B. | Another function is in process. |
| C. | Dispose valve not completely closed. |
| D. | Bulk oil tank is empty. |
| E. | Solenoid, pump or switch issue. |
JIB or vat filling slow. | A. Pump or line issues beyond the scope |
| of operator troubleshooting. |
A.Incorrect setup procedure.
Frypot won’t fill. B. Dispose valve not completely closed.
C.Bulk oil tank is empty.
D.RTI pump issue.
Corrective Action
A.Power cycle fryer by disconnecting and reconnecting
B.If a filtration or any other filter menu function is in process or
FILTER NOW? YES/NO, CONFIRM YES/NO, or SKIM VAT are displayed, wait until the process is complete and try again.
C.Ensure the dispose valve handle is pushed fully closed.
D.Call your bulk oil provider.
E.Call you ASA for assistance.
A.Contact your bulk oil provider.
A.Power cycle fryer by disconnecting and reconnecting
B.Ensure the dispose valve handle is pushed fully closed.
C.Call your bulk oil provider.
D.Call you ASA for assistance.
7.2.6 | Error Log Codes |
| |
|
|
|
|
Code |
| ERROR MESSAGE | EXPLANATION |
E01 |
| REMOVE DISCARD (Right) | A product cook is started on the right side of a |
|
|
| split vat or in a full vat that has a different |
|
|
| setpoint other than the current vat temperature. |
E02 |
| REMOVE DISCARD (Left) | A product cook is started on the right side of a |
|
|
| split vat or in a full vat that has a different |
|
|
| setpoint other than the current vat temperature. |
E03 |
| ERROR TEMP PROBE FAILURE | TEMP Probe reading out of range |
E04 |
| HI 2 BAD | High limit reading is out of range. |
E05 |
| HOT HI 1 | High limit temperature is past more than 410°F |
|
|
| (210°C), or in CE countries, 395°F (202°C) |
E06 |
| HEATING FAILURE | A component has failed in the high limit circuit |
|
|
| such as computer, interface board, contactor or |
|
|
| |
E07 |
| ERROR MIB SOFTWARE | Internal MIB software error |
E08 |
| ERROR ATO BOARD | MIB detects ATO board connection lost; ATO |
|
|
| board failure |
E09 |
| ERROR PUMP NOT FILLING | Dirty pad and it needs changed or it was |
|
|
| bypassed; filter pump problem |
E10 |
| ERROR DRAIN VALVE NOT OPEN | Drain valve was trying to open and confirmation |
|
|
| is missing |
E11 |
| ERROR DRAIN VALVE NOT CLOSED | Drain valve was trying to close and confirmation |