CHAPTER 5: FILTRATION INSTRUCTIONS

BIELA14 SERIES GEN II LOV™ ELECTRIC FRYER

CHAPTER 5: FILTRATION INSTRUCTIONS

5.1Introduction

The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation.

Section 5.2 covers preparation of the filter system for use. Operation of the system is covered in Section 5.3.

5.1Introduction WARNING

The on-site supervisor is responsible for ensuring that operators are made aware of the inherent hazards of operating a hot oil filtering system, particularly the aspects of oil filtration, draining and cleaning procedures.

The filter pad or paper MUST be replaced daily. WARNING

The filter pad or paper MUST be replaced daily.

5.2Preparing the Filter for Use

1.Pull the filter pan out from the cabinet and remove the crumb tray, hold-down

ring, filter pad (or paper), and filter screen. (See Figure 1) Clean all metal parts with a solution of All Purpose Concentrate and hot water then dry thoroughly.

The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (MSDU) to be positioned under the drain. If using an MSDU built before January 2004 see instructions on page 4- 16.

Figure 1

2.Inspect the filter pan connection fitting to ensure that both O-rings are in good condition. (See Figure 2)

Inspect the filter connection fitting O-rings.

Figure 2

5-1

Page 57
Image 57
Frymaster BIELA14 warranty Filtration Instructions, 5.1Introduction, The filter pad or paper MUST be replaced daily