4.13 Programming Level Two

The vat begins to heat. The computer displays the actual vat temperature during the test. When the temperature reaches 410°F ± 10° F (210°C ± 12°C)*, the computer displays hot hi-1alternating with the actual temperature (ex. 410F) and continues heating.

*NOTE: In computers used in the European Union (those with the CE mark), the temperature is 395°F (202°C).

The fryer continues heating until the second high limit trips. Generally this happens once the temperature reaches 423°F to 447°F (217°C to 231°C) for non-CE high limits and 405°F to 426°F (207°C to 219°C) for CE high limits.

Once the high-limit opens the computer displays HELP HI-2alternating with the actual temperature (ex. 430F).

5. Release the (1 yes) button.

If the high-limit fails, the computer displays HIGH LIMIT FAILURE alternating with DISCONNECT POWER. If this happens, disconnect power to the fryer and call for service immediately.

The vat stops heating and the computer displays the current temperature setting alternating with the actual temperature (ex. 430F) until the temperature cools below 400°F (204°C).

6. Press the soft power button to cancel the alarm.

7. Once the temperature cools below 400°F (204°C) press the (2) button once to exit the high-limit test.

8.Press the (2) button again to exit to OFF.

9.Follow the procedures on page 4-16 to dispose of the oil.

4.13 Programming Level Two

To enter Level two programming mode:

1.With the computer OFF press the TEMP and INFO buttons simultaneously for 10 seconds until LEVEL 2 is displayed; a third chirp sounds.

The computer displays ENTER Code.

2. Enter 1234.

1

2

3

4

(1234)

The computer displays level 2 program for three seconds changing to Product

comp.

4-29

Page 47
Image 47
Frymaster BIELA14 warranty Programming Level Two, comp, 1234