106-6669 INTERFACE BOARD

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

Interface Boards (cont.)

FREQUENTLY USED TEST POINTS FOR HIGH EFFICIENCY DECATHLON (HD) FRYERS

106-6669 INTERFACE BOARD

Test

Meter Setting

Pins

Test Results

 

 

 

 

12VAC Power to Controller

50 VAC Scale

1 and 3 on J3

12-18

 

 

 

 

12VDC Power to Right BL Relay

50 VDC Scale

4 on J2 and 5 on J2

12-18

 

 

 

 

12VDC Power to Left BL Relay

50 VDC Scale

7 on J1 and 5 on J2

12-18

 

 

 

 

24VAC Power to High-Limit

50 VAC Scale

6 on J2 and GROUND

22-28

 

 

 

 

24VAC Power

50 VAC Scale

2 on J2 and GROUND

22-28

 

 

 

 

24VAC Power To 24VAC Gas Valve

50 VAC Scale

7 on J2 and GROUND

22-28

 

 

 

 

Probe Resistance*

R x 1000 Ohms

10 and 11 on J2

**

 

 

 

 

*Disconnect 15-pin harness from controller before testing probe circuit.

**See Probe Resistance Chart at the end of this chapter.

 

HIGH EFFICIENCY DECATHLON (HD) FRYER

 

LED DIAGNOSTIC LIGHTS

 

(106-6669 INTERFACE BOARD)

 

 

CMP

Indicates power from 12V transformer.

24V

Indicates power from 24V transformer.

HI

Indicates output (closed) from latch relay (K4).

HT

Indicates output from heat relay (K3).

AL

Indicates output (open) from latch relay (K4).

The board contains two heat relays (K2 and K3), and two basket lift relays (K1 and K4). NOTE: On factory-original units not equipped with basket lifts and on service interface boards, the board will have no basket lift relays installed.

1-6