Installing the New Temperature Probe:

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

Installing the New Temperature Probe:

1.Feed the probe wire through the probe nipple from the top side of the frypot.

2.Loosely install the bladder nut.

3.Mount the probe into the mounting hardware.

4.Tighten the bladder nut.

5.Install the insulation and plug.

1.7.4 Replacing the High-limit Thermostat

1.Turn fryer off and drain oil from the frypot. Allow the frypot to cool completely before proceeding.

2.Perform steps 1-4 in Section 1.7.1, Replacing the Computer.

3.Remove fryer door for easier access to the temperature probe. First, remove top hinge from bracket. Then, lift door off bottom hinge pin.

4.Remove two screws securing the high-limit mounting-bracket. Do not disconnect wires from high-limit at this time.

Remove screws (arrows) securing high-limit to fryer.

5.Loosen and completely unscrew the compression nut, then the pass-through nut on the frypot bottom. Proceed to the next step before removing high-limit

from frypot.

Compression nut unscrewed. Unscrew the pass-through nut (arrow).

1-15