HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.8 Replacing the Frypot (cont.)

22.Remove the temperature probe from frypot. (See Section 1.7.3, Replacing the Temperature Probe: Computer–equipped Fryers, for specific instructions.)

23.Remove the high-limit from the frypot.

24.Remove bolts from brackets securing burner manifold to frypot. Leave the manifold in place.

Removing bolts (arrows) from burner manifold support brackets (both sides). Leave the burner manifold in place after removing bolts.

25.Using a sharp knife or box-cutter, cut the silicon seal around the frypot. Use care not to scratch stainless steel surfaces.

Cutting frypot seal prior to frypot removal.

1-26

Page 31
Image 31
Frymaster FPHD manual Cutting frypot seal prior to frypot removal