Frymaster FPHD Ignition Failure cont, Improper Burner Function, Service Procedures, The Gas Valve

Models: FPHD

1 76
Download 76 pages 53.92 Kb
Page 34
Image 34
1.8.1 Ignition Failure (cont.)

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.8.1 Ignition Failure (cont.)

The Electronic Circuits

If gas and electrical power are supplied to the fryer, the next most likely cause of ignition failure is a problem in the 24 VAC circuit of fryers equipped with electronic ignition systems, or in the pilot system for those without electronic ignition. If the fryer is equipped with a SUFF/UFF filtration system, verify that the drain valve is fully closed. (The valve is equipped with a microswitch that must be closed for power to reach the gas valve. The valve handle can appear to be closed when the microswitch is open.) If the valve is fully closed, or the fryer does not have a filtration system, refer to the troubleshooting guides in this chapter.

The Gas Valve

If the problem is not in the 24 VAC circuit or pilot system, it is most likely in the gas valve. Before replacing the gas valve, refer to the troubleshooting guides in this chapter.

1.8.2 Improper Burner Function

In these instances, the burner ignites but exhibits abnormal characteristics, such as popping, incomplete lighting of the burner, fluctuating flame intensity, and flames “rolling” out of the fryer.

Popping indicates delayed ignition. In most cases, the main gas valve is opening, but the burner is not immediately lighting. When ignition does take place, excess gas ignites rapidly rather than smoothly.

The primary causes of popping are:

1.low or fluctuating gas pressure,

2.misdirected or weak pilot flame,

3.clogged burner orifices,

4.clogged burner flame-transfer holes

5.clogged burners,

6.inadequate make-up air,

7.heat damage to the controller or ignition module,

8.an out-of-adjustment igniter or broken ignition wire,

9.a defective ignition module,

10.missing or misaligned burners,

11.clogged vent tube (causing incorrect gas pressure), or

12.make-up air is blowing down the flue.

1-29

Page 34
Image 34
Frymaster FPHD Ignition Failure cont, Improper Burner Function, High Efficiency Decathlon Series Gas Fryers, The Gas Valve