HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers

1. Disconnect the fryer from the electrical supply.

2.Drain cooking oil from the frypot. Allow the frypot to cool completely before proceeding.

3.Remove fryer door for easier access to the temperature probe. First, remove top hinge

from bracket. Then, lift door off bottom hinge pin.

Remove the fryer door for easier access to the temperature probe.

4. Disconnect the probe harness connector (arrow). Use a pin pusher to remove plug from probe wires (probe side only). Retain the plug for re-assembly on new probe.

Disconnect the two-pin probe harness connector (arrow).

5.Remove the drain manifold. Only the drain tubes directly blocking the frypot being replaced require removal.

-Remove the nuts holding the drain valve strap onto the drain tube stud.

-Disconnect the Teflon tube at the back of the center dump tube piece and any other components attached to the tubes, including drain flush flexlines.

-Loosen the nut on each clamp holding the rubber boots and drain sections together.

-Carefully remove the tubes by pulling down at an angle, straight out of the drain valves, and working them gently out of the rubber boots. Set aside for reassembly.

Remove the nuts, Teflon tube (not pictured), clamp, boot, and drain tubes.

1-12

Page 17
Image 17
Frymaster FPHD manual Replacing the Temperature Probe Computer-equipped Fryers