capillary tube cannot be repositioned.

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.4 Replacing the High-limit Thermostat (cont.)

8.Mark and disconnect wires at the high-limit in the component box.

Mark and disconnect high-limit wiring (arrows). Reconnect wires to the same terminals on the replacement high-limit.

9.Remove high-limit from fryer by pulling the capillary tube and bulb through the component box opening (arrow). This may require removal of the control panel frame.

10.Reverse the above steps for high-limit installation.

IMPORTANT: When installing new high-limit, Component box opening (arrow). ensure the capillary tube and bulb are positioned

properly with the mounting hardware installed prior to tightening the compression nut. Once tightened, the

capillary tube cannot be repositioned.