Frymaster FPHD manual High Efficiency Decathlon Series Gas Fryers, Service Procedures

Models: FPHD

1 76
Download 76 pages 53.92 Kb
Page 18
Image 18
Manual background

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers (cont.)

6.Remove the burner shield by loosening the screw on each end.

7.Remove the burner rail by loosening the screw on each end. The burner rail secures the burners in the burner manifold. Be careful to ensure that the burners do not fall out of the gas manifold, as they might be damaged and dented.

8.Remove the burners to gain access to the temperature probe and to ease frypot removal. Lean each burner slightly away from the frypot to clear the burner seal (metal box attached to frypot). Then, pull the burner up and off of the orifice. The burners should be easy to remove and do not require force.

Remove the burner rail and burner shield.

Remove burners to gain access to temperature probe (arrow).

9.Loosen and unscrew the compression nut and the pass-through nut completely from

the frypot. Proceed to the next step before removing the probe from the frypot.

Loosen and unscrew completely the compression nut (bottom arrow), then the pass-through nut (top arrow).

1-13

Page 18
Image 18
Frymaster FPHD manual High Efficiency Decathlon Series Gas Fryers, Service Procedures