HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.7.8 Replacing the Frypot (cont.)

19.If the fryer is equipped with drain-valve microswitches, mark the wires and microswitch terminals, then disconnect wires from the switch. Secure the wires to prevent damage when frypot is removed.

Left: Microswitch wires marked for removal (ensure microswitch terminals are marked the same as the wires removed). Right: Microswitch mounted to drain valve.

20.Remove the drain valve handle by loosening the drain valve nut and removing attached hardware. Depending on placement and

configuration, the valve may be turned in a different direction than pictured.

Remove the drain valve nut and attached

hardware.

21.Remove the pilot assembly from the frypot.

-If trailing pilot, disconnect the pilot supply line from the trailing pilot valve on the burner manifold.

Remove the mounting screw(s) to detach the pilot assembly from the pilot bracket.

Remove the pilot assembly from the pilot bracket on the frypot.

1-25

Page 30
Image 30
Frymaster FPHD manual Remove the drain valve nut and attached Hardware