3.Adjust the Offset/Scan scale as necessary.

Offset Setting

 

Unit:

Select ADF front or ADF back as target.

Main:

Adjusts the horizontal Offset.

 

Setting range -2mm to +3mm, in steps of 0.5mm.

Sub:

Adjusts the vertical Offset.

 

Setting range -2mm to +3mm, in steps of 0.5mm.

Vertical magnification

Adjustment

Unit:

Select ADF front or ADF back as target.

-6.3%/6.3%:

Adjusts the vertical (document length) Scan scale.

 

Setting range -6.3% to +6.3%, in steps of 0.1%.

8

SETTINGS SCANNER