When both “Start“ and “End“ positions are set to 0 (zero), a multi feed error

 

 

HINT

 

will be detected over the whole area, regardless of the setting of “Enable“

 

 

 

 

or “Disable“.

 

 

If you wish to deactivate the detection for all of the areas, please select

 

 

 

 

“Disable” and set “Start” to 0 (zero), while choosing a value greater or

 

 

equal than the document length for “End”.

If “Start” is set to a value beyond the size of a document, the detection area is as follows:

When “Disable” is selected: The whole area of the document is the detection area.

When “Enable“ is selected: Multi feed detection is disabled.

For the multi feed detection, it is necessary to specify the range for the length to at least 5 mm.

Please perform the setting for the detection area so, that following condi- tion is met:

[“End:” position] - [“Start:” Position] 6mm

You can also specify the check area by the following other methods.

By dragging the mouse on the setting area window to create rectangular

By moving the edge grip at Start or End in the setting area

Setting Example 1:Left, Disable, Start=50 mm, End=200 mmMiddle, Enable, Start=50 mm, End=200 mmRight, Disable, Start=50 mm, End=200 mm

  





(GGFKPIFKTGEVKQP

Unit: mm

 

8

SETTINGS SCANNER

8.4 Multifeed Detection 193