Chapter 2 Installation and Connection

USABLE DETACHABLE POWER SUPPLY CABLE SET

MODEL

Input

Connector

Cord

Attachment Plug cap

North

100-

IEC C-13

Type SJT, No.16 AWG Min.

NEMA (5-15P)

America

120V

Rated 13A, 125V

3-Conductors

parallel blade

<*1>

 

UL, CSA Approved

(Single phase;2-current carrying

Rated 13A, 125V

<*2>

 

 

conductors & ground)

UL, CSA Approved

 

 

 

UL, CSA Approved

 

 

 

200-

IEC C-13

Type SJT, No.14 AWG Min.

NEMA (6-15P)

 

240V

Rated 15A, 250V

3-Conductors

tandem blade

 

 

UL, CSA Approved

(Single phase; 2-current carrying

Rated 15 A, 250 V

 

 

 

conductors & ground)

UL, CSA Approved

 

 

 

UL, CSA Approved

 

 

Europe

100-

IEC C-13

CENELEC OC

Rated 10 A, 250 V

<*2>

240V

Rated 10A, 250V

3X1.0 square mm<*1>

<*1>

 

 

 

<*1>

<HAR>

 

 

Aus-

100-

IEC C-13

Cable: AS OD 3 X1.0 square mm

Rated 10 A, 250 V

tralia

240V

Rated 10A,

e.g.

 

 

 

 

250V

 

 

 

U.K

100-

IEC C-13

BS OC 3 X1.00 square mm

Rated 10 A. 250 V

<*2>

240V

Rated 10A,

 

 

 

 

 

250V

 

ASA

or

 

 

 

 

Japan

100V

IEC C-13

Type HVCTF cross section area

NEMA (5-15P)

 

 

Rated 13A,

1.25 square mm

parallel blade

 

 

125V

3-Conductors

Rated 13 A, 125 V

 

 

 

(Single phase;2-current

 

 

 

 

 

carrying conductors & ground)

 

 

 

 

METI Approved

METI Approved

METI Approved

 

 

PS or <PSE>

PS or <PSE>

PS

or <PSE>

 

 

E

E

E

 

Korea

220V

IEC 60320-1

Comply with KSC3304.

Comply with KSC8305.

 

(Class I)

(IEC C-13)

Type VCTF cross section area 1.25

Rated 12A, 250V

 

 

Rated 12A, 250V

(0.50 or 1.00 or 2.00) square mm

 

 

 

 

 

3-Conductors

 

 

 

 

 

(Single phase;2-current

 

 

 

 

 

carrying conductors & ground)

 

 

220V

IEC 60320-1

Comply with KSC3304.

Comply with KSC8305.

(Class II)

(IEC C-13)

Type VCTFK cross section area

Rated 12A, 250V

 

Rated 3A, 250V

1.25 (0.50 or 0.75 or 1.00 or 2.00)

 

 

 

square mm

 

 

 

2-Conductors

 

Note: *l. Be sure that the detachable proper Supply cord has the approval of the appropriate safety agencies of the country where the equipment will be used.

*2. Cable length of above Power Supply cord shall be shorter than 4.5 m.

IP-9610

20