Appendix

(1)Preparations

1)Check the system configuration Check the entire system configuration.

2)Check the units and cables to be connected to the device

Check the units to be connected to the device, cables that have to be procured, and installation conditions.

3)Tools and measuring instruments necessary for work:

Digital multimeter

General-purpose tools

(2)Environment check

1)Ambient air temperature, humidity and power supply

Make sure that the ambient air temperature, the humidity and power supply conform to A.2.2, “Environment Specifications.

2)Ground connection (FG)

Make sure that use a grounding resistance of 100 ohms, a wire of 2mm2 or thicker, or your country’s applicable standard.

(3)Visual check of appearance

1)Make sure that the device surface has no damage such as scratches, dirt, rust, deformation or peeling of its coating.

2)Make sure that patent nameplate and device nameplate are still attached, and that buttons are not damaged.

3)Make sure that connectors are not loose.

(4)Cable connection check

Make sure that individual cables are connected as prescribed in system specifications.

Refer to Chapter 2, “Installation and Connection,” for the connection methods, Section 4.2, “Cables and Connector Details,” and A.2.3, “Function specifications,” for device connector pin assignments.

Hardware settings need not be set in the device.

(5) Input voltage check

Make sure that the voltage of power supplied to the device is in a range of 100-240 VAC

±10%.