Table 5.12 Contents of SECURITY SET PASSWORD data

Word

 

Contents

 

 

0

Control word

 

Bit 0 Identifier

 

0

= Sets a user password.

 

1

= Sets a master password.

 

Bits 1 to 7 Reserved

 

Bit 8 Security level

 

0

= High

 

1

= Maximum

 

Bits 9 to 15 Reserved

 

 

1 to 16

Password (32 bytes)

 

 

17 to 255

Reserved

 

 

 

Table 5.13 Relationship

between combination of Identifier and Security level, and

 

operation of the lock function

 

 

 

Indentifier

Level

Description

 

 

 

User

High

The specified password is saved as a new user password. The

 

 

lock function is enabled after the device is turned off and then

 

 

on. LOCKED MODE can be canceled using the user password

 

 

or the master password already set.

 

 

 

Master

High

The specified password is saved as a new master password. The

 

 

lock function is not enabled.

 

 

 

User

Maximum

The specified password is saved as a new user password. The

 

 

lock function is enabled after the device is turned off and then

 

 

on. LOCKED MODE can be canceled using the user password

 

 

only. The master password already set cannot cancel LOCKED

 

 

MODE.

 

 

 

Master

Maximum

The specified password is saved as a new master password. The

 

 

lock function is not enabled.

 

 

 

5 - 60

C141-E056-01EN

Page 123
Image 123
Fujitsu MPC3045AH, MPC3065AH manual Contents of Security SET Password data