(22)IDLE (X'97' or X'E3')
Upon receipt of this command, the device sets the BSY bit of the Status register, and enters the idle mode. Then, the device clears the BSY bit, and generates an interrupt. The device generates an interrupt even if the device has not fully entered the idle mode. If the spindle of the device is already rotating, the
If the contents of the Sector Count register is other than 0, the automatic
If the contents of the Sector Count register is 0, the automatic
Enabling the automatic
The period of timer count is set depending on the value of the Sector Count register as shown below.
Sector Count register value | Point of timer | |
|
|
|
0 | [X'00'] | Disable of timer |
|
|
|
1 to 240 | [X'01' to X'F0'] | (Value ×5) seconds |
|
|
|
241 to 251 | [X'F1' to X'FB'] | (Value – 240) ×30 minutes |
|
|
|
252 | [X'FC'] | 21 minutes |
|
|
|
253 | [X'FD'] | 8 hours |
|
|
|
254 to 255 | [X'FE' to X'FF'] | 21 minutes 15 seconds |
|
|
|
At command issuance (I/O registers setting contents)
1F7H(CM) |
|
|
|
| X'97' or X'E3' |
| |
|
|
|
|
|
|
|
|
1F6H(DH) | × | × | × |
| DV |
| xx |
|
|
|
|
|
|
|
|
1F5H(CH) |
|
|
|
| xx |
| |
1F4H(CL) |
|
|
|
| xx |
| |
1F3H(SN) |
|
|
|
| xx |
| |
1F2H(SC) |
|
|
| Period of timer |
| ||
1F1H(FR) |
|
|
|
| xx |
| |
|
|
|
|
|
|
|
|
5 - 42 |