At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

 

DV

End head No. /LBA [MSB]

 

 

 

 

 

 

1F5H(CH)

 

End cylinder No. [MSB] / LBA

1F4H(CL)

 

End cylinder No. [LSB]

/ LBA

1F3H(SN)

 

End sector No.

/ LBA [LSB]

1F2H(SC)

 

 

 

00 (*1)

 

1F1H(ER)

 

 

 

Error information

*1 If the command is terminated due to an error, the remaining number of sectors of which data was not transferred is set in this register.

(9)RECALIBRATE (X'1x', x: X'0' to X'F')

This command performs the calibration. Upon receipt of this command, the device sets BSY bit of the Status register and performs a calibration. When the device completes the calibration, the device updates the Status register, clears the BSY bit, and generates an interrupt.

This command can be issued in the LBA mode.

At command issuance (I/O registers setting contents)

1F7H(CM)

0

0

0

1

 

x

x

x

x

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

DV

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

 

 

1F4H(CL)

 

 

 

 

xx

 

 

 

1F3H(SN)

 

 

 

 

xx

 

 

 

1F2H(SC)

 

 

 

 

xx

 

 

 

1F1H(FR)

 

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 