Fujitsu MPD3XXXAT The READ LONG command supports only single sector operation, 1F7 HCM, 1F6 HDH

Models: MPD3XXXAT

1 191
Download 191 pages 22.44 Kb
Page 107
Image 107
The READ LONG command supports only single sector operation.

The READ LONG command supports only single sector operation.

At command issuance (I/O registers setting contents)

1F7H(CM)

0

0

1

 

0

0

0

1

R

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

L

 

×

 

DV

 

Head No. /LBA [MSB]

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

Cylinder No. [MSB]

/ LBA

 

 

1F4H(CL)

 

 

Cylinder No. [LSB] / LBA

 

 

1F3H(SN)

 

 

Sector No.

 

 

/ LBA [LSB]

 

 

1F2H(SC)

 

 

Number of sectors to be transferred

 

1F1H(FR)

 

 

 

 

 

 

xx

 

 

 

R = 0 or 1

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

1F6H(DH)

×

L

 

×

 

DV

Head No. /LBA [MSB]

 

 

 

 

 

 

 

1F5H(CH)

 

 

Cylinder No. [MSB] / LBA

1F4H(CL)

 

 

Cylinder No. [LSB] / LBA

1F3H(SN)

 

 

Sector No.

 

/ LBA [LSB]

1F2H(SC)

 

 

 

 

 

00 (*1)

1F1H(ER)

 

 

 

Error information

*1 If the command is terminated due to an error, this register indicates 01.

(19)WRITE LONG (X'32' or X'33')

This command operates similarly to the READ SECTOR(S) command except that the device writes the data and the ECC bytes transferred from the host system to the disk medium. The device does not generate ECC bytes by itself. The WRITE LONG command supports only single sector operation.

This command is operated under the following conditions:

The command is issued in a sequence of the READ LONG or WRITE LONG (to the same address) command issuance. (WRITE LONG command can be continuously issued after the READ LONG command.)

If above condition is not satisfied, the command operation is not guaranteed.

5 - 40

C141-E069-02EN

Page 107
Image 107
Fujitsu MPD3XXXAT The READ LONG command supports only single sector operation, 1F7 HCM, 1F6 HDH, Head No. /LBA MSB, 00 *1