Fujitsu MPD3XXXAT Read Dma, Write Dma, Security Disable Password, Read Long, Write Long, 1F7 HCM

Models: MPD3XXXAT

1 191
Download 191 pages 22.44 Kb
Page 127
Image 127
WRITE VETIFY

READ DMA

WRITE DMA

SECURITY DISABLE PASSWORD

READ LONG

WRITE LONG

SECURITY FREEZE LOCK

READ MULTIPLE

WRITE MULTIPLE

SECURITY SET PASSWORD

READ SECTORS

WRITE SECTORS

 

 

 

 

WRITE VETIFY

 

 

At command issuance (I-O registers setting contents)

1F7H(CM)

1

1

1

1

0

1

0

1

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

DV

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

 

 

1F4H(CL)

 

 

 

 

xx

 

 

 

1F3H(SN)

 

 

 

 

xx

 

 

 

1F2H(SC)

 

 

 

 

xx

 

 

 

1F1H(FR)

 

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (I-O registers setting contents)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 

(34)SECURITY SET PASSWORD (F1h)

This command enables a user password or master password to be set.

The host transfers the 512-byte data shown in Table 1.2 to the device. The device determines the operation of the lock function according to the specifications of the Identifier bit and Security level bit in the transferred data. (Table 1.3)

Issuing this command in LOCKED MODE or FROZEN MODE returns the Aborted Command error.

5 - 60

C141-E069-02EN

Page 127
Image 127
Fujitsu MPD3XXXAT Read Dma, Write Dma, Security Disable Password, Read Long, Write Long, Security Freeze Lock, 1F7 HCM