Fujitsu MPD3XXXAT At command completion I/O registers contents to be read, 1F7HST, 1F6HDH, 1F5HCH

Models: MPD3XXXAT

1 191
Download 191 pages 22.44 Kb
Page 132
Image 132
Manual background

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

 

×

 

DV

 

Max head/LBA [MSB]

 

 

 

 

 

 

 

1F5H(CH)

 

 

Max. cylinder [MSB]/Max. LBA

1F4H(CL)

 

 

Max. cylinder [LSB]/Max. LBA

1F3H(SN)

 

 

Max. sector/Max. LBA [LSB]

1F2H(SC)

 

 

 

 

 

 

xx

1F1H(ER)

 

 

 

 

Error information