90 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
Note – The server takes about one minute to power off. Use the show /HOST
commandto determine when thehost has been powered off. The console will display
status=Powered Off.
c. Switch to the system console to view POST output.
Watchthe POST output for possible fault messages. The following output
indicates that POST did not detect any faults:
Note – Depending on the configuration of ILOM POST variables and whether POST
detected faults or not, the system might boot, or the system might remain at the ok
prompt. If the system is at the ok prompt, type boot.
d. Return the virtual keyswitch to Normal mode.
e. Switch to the system console and type the Solaris OS fmadm faulty
command.
No memory faults should be displayed.
If faults are reported, referto the diagnostics instructions described in “ILOM
TroubleshootingOverview” onpage 23 forguidance in troubleshooting the
fault.
5. Switch to the ILOM command shell.
-> start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS
-> start /SYS/console
.
.
.
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
-> set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
#fmadm faulty