
Detecting and Managing Faults 27
set /HOST/bootmode property=
value
[whereproperty is state,config,
or script]
bootmode [normal] [reset_nvram]
[config=configname][bootscript=
string]
Controlsthe host server OpenBoot
PROMfirmware method of booting.
stop /SYS; start /SYS powercycle [-f]
The -f option forcesan immediate
poweroff.Otherwise the command
attempts a graceful shutdown.
Performs a poweroff followed by
poweron.
stop /SYS poweroff [-y][-f]
•-y enables you to skip the
confirmationquestion.
•-f forcesan immediate
shutdown.
Powers offthe host server.
start /SYS poweron [-c]
•-cexecutes a console command
after completion of the poweron
command.
Powers on the host server.
set /SYS/PSx
prepare_to_remove_action=
true
removefru /SYS/PS0 |
/SYS/PS1
Indicates if it is okay to perform a
hot-swap of a power supply.This
command does not perform any
action. But this command provides
a warning if the power supply
should not be removedbecause the
other power supply is not enabled.
reset /SYS reset [-y] [-c]
•-y enables you to skip the
confirmationquestion.
•-cexecutes a console command
after completion of the reset
command.
Generates a hardwarereset on the
host server.
reset /SP resetsc [-y]
•-y enables you to skip the
confirmationquestion.
Reboots the service processor.
set /SYS keyswitch_state=
value
normal | standby | diag |
locked
setkeyswitch [-y] value
normal |standby |diag |
locked
•-y enables you to skip the
confirmationquestion when
setting the keyswitch to stby.
Sets the virtual keyswitch.
TABLE: Service-RelatedCommands (Continued)
ILOMCommand ALOMCMT Command Description