28 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
set /SYS/LOCATE value=value
[Fast_blink |Off]
setlocator value
[on |off]
Turnsthe Locator LED on the server
on or off.
(No ILOM equivalent.) showenvironment Displays the environmentalstatus
of the host server.This information
includes system temperatures,
power supply,front panel LED,
harddrive, fan, voltage, and current
sensor status. See “Display FRU
Information Withthe show
Command” on page 32.
show faulty showfaults [-v] Displays currentsystem faults. See
“Faults Displayed by show
faulty” on page 29.
(No ILOM equivalent.) showfru[-g lines][-s|-d][FRU]
•-g lines specifiesthe number of
lines to display beforepausing
the output to the screen.
•-s displays static information
about system FRUs (defaults to
all FRUs, unless one is specified).
•-ddisplays dynamic information
about system FRUs (defaults to
allFRUs, unless one is specified).
See “Display FRU Information
Withthe show Command” on
page32.
Displays information about the
FRUs in the server.
show /SYS keyswitch_state showkeyswitch Displays the status of the virtual
keyswitch.
show /SYS/LOCATE showlocator Displays the current state of the
Locator LED as either on or off.
show /SP/logs/event/list showlogs [-b lines |-e lines |
-v] [-g lines][-p
logtype[r|p]]]
Displays the history of all events
logged in the service processor
event buffers(in RAM or the
persistent buffers).
show /HOST showplatform [-v] Displays information about the
operating state of the host system,
the system serial number,and
whether the hardwareis providing
service.
TABLE: Service-RelatedCommands (Continued)
ILOMCommand ALOMCMT Command Description