20 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009
Check if the fault is
environmental.
(Flowchart item 6)
Determine if the fault is an environmentalfault or a
configurationfault.
If the fault listed by the show faulty command
displays a temperatureor voltagefault, then the fault is
an environmentalfault. Environmental faults can be
caused by faulty FRUs (power supply or fan), or by
environmentalconditions such as when computer room
ambient temperatureis too high, or the server airflow is
blocked.When the environmental condition is corrected,
the fault will automatically clear.
If the fault indicates that a fan or power supply is bad,
you can perform a hot-swap of the FRU. Youcan also
use the fault LEDs on the server to identify the faulty
FRU (fans and power supplies).
“Faults Displayed by show
faulty” on page 29
Determine if the
fault was detected
by PSH.
(Flowchart item 7)
If the fault displayed included a uuid and sunw-msg-id
property,the fault was detected by the Solaris Predictive
Self-Healing software.
If the fault is a PSH detected fault, refer to the PSH
Knowledge Article web site for additional information.
The Knowledge Article for the fault is located at the
following link:
(http://www.sun.com/msg/message-ID)
wheremessage-ID is the value of the sunw-msg-id
propertydisplayed by the show faulty command.
After the FRU is replaced, perform the procedureto
clear PSH detected faults.
“ManagingFaults Using the
PSH Feature” on page 43
“Clear PSH-Detected
Faults” on page 47
Determine if the
fault was detected
by POST.
(Flowchart item 8)
POSTperforms basic tests of the server components and
reportsfaulty FRUs. When POST detects a faulty FRU, it
logs the fault and if possible, takes the FRU offline.
POST detected FRUs display the following text in the
fault message:
Forced fail reason
In a POST fault message, reason is the name of the
power-onroutine that detected the failure.
“Detecting Faults With
POST” on page 34
“Clear POST-Detected
Faults” on page 41
Contact technical
support.
(Flowchart item 9)
The majority of hardwarefaults are detected by the
server’s diagnostics. In rare cases a problem might
requireadditional troubleshooting. If you are unable to
determinethe cause of the problem, contact your service
representativefor support.