Furuno FR-8252, FR-8062 Advanced-level Troubleshooting, Advanced-level troubleshooting, Echo menu

Models: FR-8062 FR-8122 FR-8252

1 129
Download 129 pages 39.58 Kb
Page 114
Image 114

6. MAINTENANCE & TROUBLESHOOTING

6.7Advanced-level Troubleshooting

This paragraph describes how to cure hardware and software troubles which should be carried out by qualified service personnel.

 

 

 

This radar equipment contains complex modules in which fault diagnosis and repair

 

Note

 

 

 

down to component level are not practical by users.

 

 

 

 

 

 

 

 

Advanced-level troubleshooting

 

 

 

 

 

 

 

 

 

Problem

 

Probable cause or

 

Remedy

 

 

check points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power cannot be

1)

Blown fuse.

1)

Replace blown fuse.

 

turned on

 

2)

Mains voltage/polarity

2)

Correct wiring and input voltage.

 

 

 

 

3)

Power supply board

3)

Replace power supply board.

 

 

 

 

 

 

 

 

Brilliance adjusted

1)

SPU Board

1)

Replace SPU board.

 

but no picture

 

 

 

 

 

 

 

 

 

 

 

 

Antenna not rotating

1)

Antenna drive mechanism

1)

Replace antenna drive mechanism.

 

 

 

 

 

 

 

 

Data and marks not

1)

SPU board

1)

Replace SPU board.

 

displayed in Transmit

 

 

 

 

 

status

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjust GAIN with A/C

1)

Signal cable between

1)

Check continuity and isolation of coaxial

 

SEA set at minimum.

 

antenna and display unit

 

cable.

 

Marks and indications

2)

IF amplifier

2)

Replace IF amplifier.

 

appear but no noise

3)

Video amplifier board

3)

Check coax line for secure connection. If

 

or echo

 

 

 

 

connection is good, replace SPU board.

 

 

 

 

 

 

 

 

Marks, indications

1)

Magnetron

1)

Check magnetron current.

 

and noise appear but

2)

Modulator board

2)

Replace modulator board.

 

no echo (Transmis-

3)

SPU board

3)

Replace SPU board.

 

sion leak repre-

 

 

 

 

 

senting own ship

 

 

 

 

 

position is absent)

 

 

 

 

 

 

 

 

 

 

 

 

Picture not updated

1)

Bearing signal generator

1)

Check that signal cables are fastened

 

or picture freeze-up

 

 

 

securely.

 

 

 

 

2)

SPU board

2)

Replace SPU board.

 

 

 

 

3)

Video freeze-up

3)

Turn the radar off and on.

 

 

 

 

 

 

 

 

Radar is properly

1)

2nd trace echo rejector is

1)

Turn off the 2nd-trace echo rejector, from

 

tuned but sensitivity is

 

ON.

 

the Echo menu.

 

poor

 

2)

Dirt on radiator face

2)

Clean radiator.

 

 

 

 

3)

Deteriorated magnetron

3)

With the radar transmitting on 48 nm

 

 

 

 

 

 

 

range, check magnetron current. If cur-

 

 

 

 

 

 

 

rent is below normal, magnetron may be

 

 

 

 

 

 

 

defective. Replace the magnetron.

 

 

 

 

4)

Detuned MIC

4)

Check MIC detecting current. If it is below

 

 

 

 

 

 

 

normal value, MIC may have become

 

 

 

 

 

 

 

detuned.

 

 

 

 

 

 

 

 

Range changed but

1)

Defective range key

1)

Try to operate the RANGE key. If unsuc-

 

radar picture does not

 

 

 

cessful, replacement of the keypad may

 

change

 

 

 

 

be necessary.

 

 

 

 

2)

SPU board

2)

Replace SPU board.

 

 

 

 

3)

Video freeze-up

3)

Turn radar off and on.

 

 

 

 

 

 

 

 

6-6

Page 114
Image 114
Furuno FR-8252, FR-8062, FR-8122 manual Advanced-level Troubleshooting, Advanced-level troubleshooting, Echo menu