6. MAINTENANCE & TROUBLESHOOTING

6.5Trackball Maintenance

If the cursor skips or moves abnormally, you may need to clean the trackball.

1.Turn the retainer ring counterclockwise 45° to unlock it.

2.Remove the retainer ring and ball.

3.Clean the ball with a soft lint-free cloth, and blow carefully into the ball-cage to dislodge dust and lint.

4.Look for a build-up of dirt on the metal rollers. If dirty, clean the rollers with a cotton swab moist- ened lightly with isopropyl-rubbing alcohol.

5.Make sure that fluff from the swab is not left on the rollers.

6.Replace the ball and retainer ring. Be sure the retainer ring is not inserted reversely.