Furuno FR-8062, FR-8252 manual Measuring the Range and Bearing Between Two Targets, EBL reference

Models: FR-8062 FR-8122 FR-8252

1 129
Download 129 pages 39.58 Kb
Page 37
Image 37

1. OPERATIONAL OVERVIEW

1.18.2EBL reference

The EBL readout is affixed by "R" (relative) if it is relative to own ship's heading, "T" (true) if it is referenced to the north. You may choose relative or true in the head-up modes; in all other modes it is always TRUE. True bearing requires a heading sensor.

1.Press the MENU key to open the menu.

2.Choose the Mark menu and press the ENTER key.

3.Choose EBL Reference and press the ENTER key.

Relative

True

4.Choose Relative or True as appropriate and press the ENTER key.

5.Press the MENU key to close the menu.

1.19Measuring the Range and Bearing Between Two Targets

You may shift the origin of the EBL to measure the range and bearing between two targets.

1.Press the EBL key to choose the bearing indication of No. 1 EBL or No. 2 EBL (whichever you want to use). (The currently active marker is enclosed with >.....<).

2.Place the cursor on target A.

3.Press the OFFCENTER key to shift the EBL origin to the location chosen at step 2. Use the trackball to bisect target B with the EBL.

4.Use the VRM key to display the VRM having the same number as the EBL activated at step 1.

5.Roll the trackball to set the VRM on the inner edge of target B.

6.Read the bearing and range indica- tions at the bottom of the screen.

No. 1

EBL

 

 

 

+Tgt B

No. 1

 

 

 

 

 

 

 

 

Tgt

A

 

VRM

 

 

 

EBL origin

 

EBL1 >140.0°R<

EBL2 335.2°R

No. 2

EBL

+Tgt D

No. 2

VRM

Tgt C

VRM1>0.500NM<

VRM2 0.980NM

To return the origin of an EBL to the screen center, choose appropriate EBL with the EBL key, press the OFF- CENTER key followed by the ENTER key. Pressing the OFFCENTER key alone places the EBL origin at the screen center and cursor location alter- nately.

Range/bearing

Range/bearing

between targets A and B

between targets C and D

1-23

Page 37
Image 37
Furuno FR-8062, FR-8252, FR-8122 manual Measuring the Range and Bearing Between Two Targets, EBL reference