6. MENU OPERATION

6.13Setting Scan Frequencies

The Scan freq menu determines which DSC routine and distress frequencies to scan. Follow the instructions below to select/deselect DSC routine and distress frequencies to scan.

1.Press the #/SETUP key.

2.Rotate the ENTER knob to choose USR SETUP, and push the ENTER knob.

3.Rotate the ENTER knob to choose SCAN FREQ, and then push the ENTER knob to display the Scan freq setup menu.

 

 

**

Scan freq

setup

*

 

ROUTINE

DISTRESS

 

F1

:

2M-INTL

 

2M

: FIXED

 

F2

:

4M-INTL

4M

: ON

 

F3

:

6M-INTL

6M

: ON

 

F4

:

8M-INTL

8M

: FIXED

 

F5

: 12M-INTL

12M

: ON

 

F6

: 16M-INTL

16M

: OFF

Distress and safety frequencies

1.Rotate the ENTER knob clockwise to shift the cursor to the DISTRESS column.

2.Rotate the ENTER knob to choose the frequency band and then push the ENTER knob. For example, choose 4 MHz.

 

 

**

Scan freq

setup

*

 

 

ROUTINE

DISTRESS

 

F1

:

2M-INTL

 

2M

:

 

 

OFF

 

 

 

 

 

 

 

F2

:

2M-INTL

 

4M

:

 

 

ON

 

 

 

F3

:

4M-INTL

 

6M

 

:

 

ON

 

 

 

 

 

 

F4

:

8M-INTL

 

8M

: FIXED

 

F5

: 12M-INTL

12M

: ON

 

F6

: 16M-INTL

16M

: OFF

3.Rotate the ENTER knob to choose ON or OFF as appropriate and then push the ENTER knob.

4.Press the CANCEL key three times to return to the radiotelephone screen.

Note: Regulations require that 2 MHz and 8 MHz and one more DSC distress frequency be watched continuously. 2 MHz and 8 MHz cannot be turned off. Maximum three bands may be turned off.