6. MENU OPERATION

Default: ON

 

OFF

Disables/enables alarm for received Safety and

 

ON

 

Routine calls.

 

 

 

 

Rotate

ENTER

knob to choose.

****Alarm setup ***

INTERNAL ALARM

: OFF

POSITION OLDER

:4.0 H

EXT ALARM : DSTRS/URG

ALARM DISTANCE: 500 NM

Default: 4.0 hours

 

4.0

 

Alarm is output when position is older by the

 

3.0

 

number of hours set here.

 

2.0

 

 

 

1.0

 

 

 

0.5

 

 

 

 

 

 

Default: DSTRS/URG

Default: 500 NM

 

 

DSTRS/URG

 

 

 

 

 

ROUTINE

 

 

OFF

 

ALL

 

500 NM

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Enable or disable reception of the distress alarm received from a ship in distress which is more than 500 miles from own ship.

Sets type of call to be output to the IC-303.

DSTRS/URG: Distress or urgency

 

call output upon receipt.

ROUTINE:

Routine call output

 

upon receipt.

ALL:

All calls output.

OFF:

No output.

6.10Sound Setting

The SOUND menu lets you set the volume for the following items:

Key click on/off

Volume of the receiving alarm for the safety and routine messages

Volume of the receiving alarm for the distress and urgency

1.Press the #/SETUP key.

2.Rotate the ENTER knob to choose USR SETUP, and push the ENTER knob.

3.Rotate the ENTER knob to choose SOUND, and push the ENTER knob.

 

 

 

 

 

 

 

 

 

 

 

 

 

Turns on/off beep generated when

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

Default: ON

 

 

keyboard is operated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

Note: Do not confuse keyboard beep

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(single beep) with ACK beep

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***

Sound setup

***

 

 

 

 

 

 

 

 

 

(three beeps).

 

 

 

 

 

 

 

 

 

 

 

 

Rotate ENTER knob

 

 

 

 

 

 

 

ORDINARY ALARM

 

 

 

KEY CLICK

: ON

 

 

 

 

to set.

 

 

 

VOLUME (0~63)

 

 

 

 

ORDINARY ALARM : 30

 

 

 

47

Sets loudness of Safety,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Routine and Old Position

 

DISTRESS ALARM : 63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

alarms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISTRESS ALARM

VOLUME (38~63)

63

Rotate ENTER knob to set.

Sets loudness of Distress and Urgency alarms.

6-17

Page 115
Image 115
Furuno FS-5070 manual Sound Setting, Sound setup