4. DISTRESS OPERATIONS

The display changes as below (example).

Compose msg.

 

MSG TYPE

: DISTRESS

 

NATURE

: FLOODING

 

POS: 35°00.0000N

 

 

135°00.0000E

AT 12:34

 

COMM MODE

:

TELEPHONE

 

 

 

 

 

DSC FREQ

:

2187.5 kHz

 

 

 

 

GO TO VIEW

16.Press the DISTRESS button more than four seconds to send the distress alert.

Distress alert message in progress!

 

NATURE: FLOODING

 

POS: 35°00.0000N

AT 12:34

 

 

135°00.0000E

 

TELEPHONE

2182.0 kHz

 

DSC FREQ :

2187.5 kHz

 

TIME TO GO : 38S

 

 

17.When the distress acknowledge call is received, use the telephone or telex to communicate.

For telephone, follow step 3 on page 4-3. For NBDP, follow the procedure below.

Communicating by NBDP Terminal Unit

The message “STATION ENTRY COMPLETED FROM DSC. Press any key to escape.” Appears on the NBDP’s display.

1.Press any key on the NBDP Terminal Unit to erase the message.

2.Press the function key F3 on the keyboard of the NBDP Terminal Unit to show the Operate menu.

3.Choose “Call Station” and then press the Enter key.

 

 

 

 

 

 

 

 

Call Station

 

 

 

 

 

 

 

 

 

Station

List

 

Station Set up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Station

: DSC

 

 

 

 

 

DSC

 

 

 

 

 

 

 

 

ABC-6M

 

 

ID Code

:

 

 

 

 

 

 

ABC-12M

 

 

Mode

: ARQ FEC

 

 

 

 

 

ABC-8M

 

 

Tx Freq

: 2174.50

 

 

 

 

 

 

FURUNO

 

 

Rx Freq

: 2174.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.“DSC” is selected; press the Enter key to connect the communications line. “Connect” appears in reverse video.

5.Type and transmit your message, giving the following information:

Ship’s name and call sign

Nature of distress and assistance needed

Description of your vessel

6.Press the function key F10 (BREAK) to disconnect the line.

For NBDP details, see Chapters 7 through 10.

4-6