11. MAINTENANCE & TROUBLESHOOTING

11.2Maintenance

Regular maintenance is vital for maintaining performance. Following the procedures below will help keep the equipment in top operating condition.

Maintenance check points

Item

Check Point

Remedy/Remarks

Antenna

Check for physical damage and

Replace damaged parts.

 

corrosion.

 

 

Wire

Check that the antenna is properly

If necessary, re-span antenna.

antenna

spanned and separated sufficiently

 

 

 

from metallic structures.

 

 

Insulators

Check for salt water deposits on

Replace damage insulators. Remove

for antenna

insulators. Check that connection at

salt water deposits. Clean with fresh

 

the lead-in insulator is tight and

water, then dry. Remove rust, then

 

rust-free.

tighten bolts and lock nuts. Cover

 

 

 

metallic surface with sealing

 

 

 

compound.

Antenna

Check condition of antenna terminal,

Tighten loosened

coupler

 

ground, coaxial cable and control

 

connections.

 

cable.

Fasten lid firmly and evenly to

 

Check that coupler lid and cable

 

prevent water leakage.

 

 

glands are firmly secure.

Replace if damaged.

 

 

Check for physical damage, corrosion

 

 

 

 

and salt water deposits.

 

 

Control

Check ground connection, control

Tighten loosened

unit

 

cable, and external equipment.

 

connections; remove foreign

 

 

Confirm that there are no objects on

 

material from connectors.

 

the top of the control unit.

Remove any objects.

 

Remove dust from control unit with

Wipe the LCD carefully to

 

 

soft cloth.

 

prevent scratching, using

 

Note: Do not use chemical cleaners to

 

tissue paper and an LCD

 

 

cleaner. To remove dirt or salt

 

clean the control unit; they can remove

 

deposits, use an LCD cleaner,

 

paint or markings or deform the

 

wiping slowly with tissue

 

equipment.

 

paper so as to dissolve the

 

 

 

 

dirt or salt. Change paper

 

 

 

 

frequently so the salt or dirt

 

 

 

 

will not scratch the LCD.

Transceiver

Check connection at signal cable,

Tighten loosened connections;

unit

 

coaxial cable, control cable, power

 

remove foreign material from

 

 

cable, and navigator.

 

connectors.

 

Confirm that there are no objects on

Remove any objects.

 

 

the top of the cabinet.

 

 

Power supply

Check that the supply voltage at

If not within the range, check

 

 

transmission is within the rated range

 

ship’s mains or ship’s battery.

 

 

(21.6 to 31.2 VDC at the power

 

Low voltage may cause

 

 

connector).

 

erratic operation.

11-2

Page 170
Image 170
Furuno FS-5070 manual Maintenance, 11-2