11.MAINTENANCE & TROUBLESHOOTING

11.3Simple Troubleshooting

The table below provides possible problems and the means with which to restore normal operation. If normal operation cannot be restored, do not attempt to check inside the equipment. Any servicing should be referred to a qualified technician.

Problem

Probable cause

Remedy

Power cannot be

Mains switchboard may be off.

Turn on the mains switchboard.

turned on.

(DC) voltage is too high.

Check supply voltage.

Battery may have discharged, Recharge battery and tighten battery

 

 

or poor contact at terminals.

 

terminals.

 

Display

Contrast is too low.

Operate the 9/

 

 

 

 

 

key to adjust

indications do not

 

 

 

contrast.

 

appear but key

 

 

 

 

 

 

 

 

 

 

 

lamps are lit.

 

 

 

 

 

 

 

 

 

 

 

Power is on but

Loudspeaker is off.

Operate the 7/

 

 

 

 

key to turn on the

 

 

no sound from

 

 

 

loudspeaker.

 

loudspeaker.

 

 

 

 

 

 

 

 

 

 

 

Poor articulation

Wrong class of emission may

Class of emission should match that of

 

 

be in use.

 

incoming signal.

 

Output power

Power is automatically reduced

Wait until the unit returns to normal

reduced to LOW

 

to protect against overheating

 

condition.

 

 

 

due to continuous transmission.

 

 

 

 

 

 

 

 

 

Antenna coupler

Antenna may be disconnected

Check antenna connection.

cannot tune

 

or shorted to ground.

Recommended length is 10 to 18

antenna

Antenna is out of tunable

 

meters.

 

 

length.

Check coupler ground.

 

Poor grounding of antenna

Checks mains voltage and polarity.

 

coupler.

 

If normal, reset breaker.

 

Breaker in coupler has tripped.

Check cable.

 

 

Connection cable loosened or

 

 

 

 

 

 

 

 

 

 

 

disconnected.

 

 

 

 

 

 

 

 

 

The message

Input has been switched from

Press the CANCEL key. The output

“Ship’s mains

 

AC to DC when AC FAIL line of

 

power can be increased on the RT

failure” appears,

 

AC/DC power supply unit

 

display. Note that the output power

and Output power

 

PR-850A is connected to

 

remains “HIGH” when it occurs while

indicator blinks.

 

FS-5070.

 

sending the distress call. When AC

Transmission

 

 

 

power is restored, this problem is

power is

 

 

 

automatically resolved.

decreased to

 

 

 

 

 

 

 

 

 

 

 

LOW2.

 

 

 

 

 

 

 

 

 

 

 

(FS-5070 only)

 

 

 

 

 

 

 

 

 

 

 

After turning on

After turning on the NBDP

Turn on the control unit before turning

the power, the

 

terminal unit, you have turned

 

on the NBDP terminal unit.

initial screen

 

on the control unit.

 

 

 

 

 

 

 

 

 

appears

 

 

 

 

 

 

 

 

 

 

 

continuously.

 

 

 

 

 

 

 

 

 

 

 

(The RT screen

 

 

 

 

 

 

 

 

 

 

 

should appear

 

 

 

 

 

 

 

 

 

 

 

after the initial

 

 

 

 

 

 

 

 

 

 

 

screen is erased.)

 

 

 

 

 

 

 

 

 

 

 

11-3

Page 171
Image 171
Furuno FS-5070 manual Simple Troubleshooting, 11-3