D. LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS – MULTIPLE HEATERS (utilizing a fan center relay)

Ground

NNeutral

L1 Hot (120V)

Fused Disconnect switch

CNO

24V

coil

R

G

 

Receptacle

 

Continue To

 

Additional

 

Heaters

Burner Control Box

Power Supply

Cord (120V)

 

C

C

TH

TH

Fan Center Relay Part No. 30169000

Low voltage

Contact Rating: 120V, 40VA, 12A

(maximum of 6 heaters per relay)

thermostat (24V)

Jumper factory installed for optional 24V thermostat

16.0) VENTING

CARBON MONOXIDE HAZARD

Heaters installed in an unvented mode require a minimum ventilation flow of 4 CFM per 1,000 Btu/hr of total installed capacity.

In buildings with airborne contamination such as poultry houses the heater must be installed with fresh air for combustion.

Failure to do so may result in death, serious injury, property damage or illness from Carbon Monoxide poisoning.

A.BASIC FLUE VENTING — Venting must comply with the latest edition of the National Fuel Gas Code (ANSI Z223.1-latest edition) or the authority having jurisdiction. Other venting references are in the equipment volume of the ASHRAE Handbook.

Model

Heat

Maximum vent length ft.

Maximum Fresh air

Max. combination of

 

exchanger

(4” diameter)

intake length ft (4”

fresh air and vent ft. (4”

 

length ft

 

diameter)

diameter)

PTS/U 40

20

45

50

75

PTS/U 50

20

45

50

75

PTS/U 50

30

35

40

65

PTS/U 75

20

45

50

75

PTS/U 75

30

35

40

65

PTS/U 100

30

45

50

75

PTS/U 100

40

35

40

65

PTS/U 125

30

60

50

75

PTS/U 125

40

50

40

65

PTS/U 125

50

40

30

55

PTS/U 150

40

60

50

75

PTS/U 150

50

50

40

65

PTS/U 150

60

40

30

55

PTS/U 175

50

60

50

75

PTS/U 175

60

50

40

65

PTS/U 175

70

40

30

55

PTS/U 200

50

60

40

65

PTS/U 200

60

50

30

55

PTS/U 200

70

40

30

45

Vent lengths shown in the table are for horizontal and vertical venting. If a longer length of vertical or horizontal venting is required contact the manufacturer for assistance with vent sizing.

 

Form #43343330

–34–

May 08

Page 35
Image 35
Gas-Fired Products PTU Series, PTS Series manual Venting, Carbon Monoxide Hazard