3.Hold the spring retainer clamp and pull the TISS wire assembly to end of reflector at overlap joint. Slide spring retainer clamp over end of reflector as shown.

Step 3

Thimble

Wire & Sleeving

 

Assembly

End View

 

TISS Wire Assembly

Spring

Spring

PN 44176000

Retainer Clamp

 

 

 

4.After attachment of the TISS, check to make sure that there is sufficient tension on the wire. Follow the diagram below to increase or decrease the tension as necessary.

1.Measure the extension of the spring from the end of the reflector to the thimble as shown below.

11” extension

Thimble

Wire & Sleeving

 

Assembly

Step 4

Spring

 

If the extension is less than 11” follow the

Spring

instruction below to increase the extension.

Retainer Clamp

 

 

Reflector End

2. Tape one end of the sleeve to the burner box or use a marker.

3. Mark the other end of the sleeve with tape or other marker. Use the top of the retainer as a reference.

4. Loosen screws.

5. Pull one end of the sleeve and wire inside until the marker is raised by the total adjusment length. ie. if the extension is 10” then pull through 1” to increase the exension to 11”.

6. Tighten screws.

7. Check extension using the method in step 1.

 

Form #43343330

–26–

May 08

Page 27
Image 27
Gas-Fired Products PTU Series, PTS Series manual End View