Note1: When the PTS / PTU is operated by a thermostat interrupting the line voltage (120V) to the heater then the post purge function is disabled.

If the flame is not sensed during sequence T3 then the burner will automatically begin re-ignition sequence T2. The ignition sequence will be repeated three times with a 60 second inter-purge. If the flame is not re-established the heater will go to lockout.

20.0) BURNER COMPONENT LOCATIONS

2

9

Note: This panel

4

3

must remain closed

for burner operation.

22

34

17

14 15

16

13

18

19

 

 

 

Legend:

30

6

 

32

31

 

 

 

 

7

 

 

8

12

 

 

 

33

 

 

 

 

10

 

11

3

5

 

 

 

 

 

 

Note: This panel

 

 

 

 

must remain closed

 

 

 

 

for burner operation.

23

 

 

24

 

 

 

 

 

21

 

 

26

35

25

20

27

1

28

29

1Cabinet Assembly

2 Access Panel - Top

3 Access Panel - Hinged (2 ea)

4 Access Panel - LH Burner

5 Access Panel - RH Burner

6 Air Inlet Screen

7 Gas Inlet Connection - 1/2”NPT

8 Power Supply Cord - 120V

9 Burner Sight Glass

10 Indicator Light - Amber (Gas Valve)

11 Indicator Light - Red (Air Switch)

12 Tube Flange Connection

13 Main Burner

14 Flame Screen (200m/BTU units only)

15 Electrode

16 Flame Sensor

17 Main Burner Orifice

18 Air Restrictor Plate

19Gas Control Valve

20Ignition Module

21Ignition Cable

22Blower Assembly

23Transformer - 120/24 VAC

24Terminal Block/Fishpaper Shield

25Air Switch

26Air Sensing Tube (P1+)

27Air Sensing Tube (P2-)

28Manifold Pipe

29Manifold Support Bracket/Clamp

30Terminal Block (24V thermostat)

31Terminal Block (TISS connection)

32Starting Collar

33Valve Holder Plate

34Fuseholder/Fuse (2 amp)

35Combustion Air Plate

Form #43343330

 

May 08

–41–

Page 42
Image 42