MULTIPURPOSE METER
USE MICROAMP SCALE

IGNITION MODULE DIAGNOSTICS

Flame Fault

If at any time the main valve fails to close completely and maintains a flame, the full time flame sense circuit will detect it and energize the combustion blower. Should the main valve later close completely removing the flame signal, the combustion blower will power off following the post purge period.

Fault Conditions

Error Mode

LED Indication

 

 

Internal Control Failure

Steady On

Air Flow Fault

1 Flash

Gas valve failure (stuck open)

2 Flashes

Ignition Lockout

3 Flashes

The LED located on the ignition module will flash ON for ¼ second, then OFF for ¼ second during a fault condition. The pause between fault codes is 3 seconds.

Flame Sensor Current Check

 

FC-

BLACK (-)

 

RED (+)

S1

FC+

 

GND

 

LED Display

V2

 

(R)24VAC

L1

IND

NC

V1

P.SW

(W)TH

Ignition Module (Fenwal)

24.0)

 

INSTALLATION DATA

 

 

 

 

 

 

 

 

 

 

 

 

Date of Installation:

 

# of Heaters in System:

 

 

Serial No.

 

 

 

 

 

 

 

 

 

 

 

 

N = Natural Gas

Model:

PTS or PTU

 

 

 

L = Propane Gas

Form #43343330

 