Controller events

 

 

 

 

 

Controller Event Messages

Description

Cause

Action

 

 

 

 

 

Resync Started

A stripe synchronization of a

A controller fails or

No action

 

RAID 5/50 set has started.

is powered off

necessary.

 

This will be done when a

during a RAID

 

 

 

controller fails or when

5/50 write

 

 

 

powered off during a write.

operation.

 

 

 

 

 

 

 

Resync Completed

A stripe synchronization of a

A controller fails or

No action

 

RAID 5/50 set has

is powered off

necessary.

 

completed.

during a RAID

 

 

 

 

5/50 write

 

 

 

 

operation.

 

 

 

 

 

 

 

UPS Failure

This indicates that an

UPS has been

Check the UPS

 

attached UPS (if configured)

disconnected or

monitoring

 

has failed.

communications

connections.

 

 

with the UPS has

Check the UPS, if

 

 

failed.

necessary replace

 

 

 

it.

 

 

 

 

 

UPS OK

This indicates that an

UPS is connected.

No action

 

attached UPS (if configured)

 

necessary.

 

is functioning correctly.

 

 

 

 

 

 

 

 

Voltage Error: Monitored

This indicates that the

Voltage regulator

Replace the

Voltage: xx.yyV

specified voltage has

hardware failure.

controller. Contact

 

exceeded limits. This is a

Enclosure 5V or

Technical Support.

 

serious error, and should be

 

 

 

12V problem in the

Replace the

 

reported to Technical

 

power supply.

defective power

 

Support.

 

 

supply.

 

 

 

 

 

 

 

 

www.gateway.com

183