| Controller events | |
|
|
|
|
|
Controller Event Messages | Description | Cause | Action | |
|
|
|
|
|
Resync Started | A stripe synchronization of a | A controller fails or | No action | |
| RAID 5/50 set has started. | is powered off | necessary. | |
| This will be done when a | during a RAID |
|
|
| controller fails or when | 5/50 write |
|
|
| powered off during a write. | operation. |
|
|
|
|
|
|
|
Resync Completed | A stripe synchronization of a | A controller fails or | No action | |
| RAID 5/50 set has | is powered off | necessary. | |
| completed. | during a RAID |
|
|
|
| 5/50 write |
|
|
|
| operation. |
|
|
|
|
|
|
|
UPS Failure | This indicates that an | UPS has been | Check the UPS | |
| attached UPS (if configured) | disconnected or | monitoring | |
| has failed. | communications | connections. | |
|
| with the UPS has | Check the UPS, if | |
|
| failed. | necessary replace | |
|
|
| it. | |
|
|
|
|
|
UPS OK | This indicates that an | UPS is connected. | No action | |
| attached UPS (if configured) |
| necessary. | |
| is functioning correctly. |
|
|
|
|
|
|
|
|
Voltage Error: Monitored | This indicates that the | Voltage regulator | Replace the | |
Voltage: xx.yyV | specified voltage has | hardware failure. | controller. Contact | |
| exceeded limits. This is a | Enclosure 5V or | Technical Support. | |
| serious error, and should be |
|
| |
| 12V problem in the | Replace the | ||
| reported to Technical | |||
| power supply. | defective power | ||
| Support. | |||
|
| supply. | ||
|
|
| ||
|
|
|
|
|
www.gateway.com | 183 |