Chapter 9: Event Logs

SES Event Messages

Description

Cause

Action

 

 

 

 

Encl.yy Temp. zz <aa>C

The controller has detected

Temperature

If the fans are set

Critical WWN: xx xx xx xx

that the indicated

sensors are

to automatic

xx xx xx xx

temperature sensor has

reporting

speed control,

 

reached a critical limit.

enclosure

place the jumper

 

 

temperatureshave

on the cooling fan

 

 

reached the

module circuit

 

 

threshold of 50°C.

board to force the

 

 

 

fans to high speed.

 

 

 

If the environment

 

 

 

ambient

 

 

 

temperature is

 

 

 

high, reduce the

 

 

 

ambient

 

 

 

temperature.

 

 

 

Make sure that the

 

 

 

airflow is not

 

 

 

blocked or

 

 

 

restricted on the

 

 

 

enclosure.

 

 

 

 

Encl.xx Alarm zz is OFF

All conditions are normal or

No condition being

No action

WWN: yy yy yy yy yy yy

the alarm is off.

reported.

necessary.

 

 

Alarm silenced.

User pressed the

 

 

 

Alarm Silence

 

 

 

button on the front

 

 

 

panel.

 

 

 

 

Encl.xx Alarm zz is ON

Alarm is on.

A condition

Press the Alarm

WWN: yy yy yy yy yy yy

 

caused the alarm

Silence button on

 

 

to sound.

the front panel and

 

 

 

isolate the cause

 

 

 

of the alarm.

 

 

 

 

194