Chapter 9: Event Logs
SES Event Messages | Description | Cause | Action |
|
|
|
|
Encl.yy Temp. zz <aa>C | The controller has detected | Temperature | If the fans are set |
Critical WWN: xx xx xx xx | that the indicated | sensors are | to automatic |
xx xx xx xx | temperature sensor has | reporting | speed control, |
| reached a critical limit. | enclosure | place the jumper |
|
| temperatureshave | on the cooling fan |
|
| reached the | module circuit |
|
| threshold of 50°C. | board to force the |
|
|
| fans to high speed. |
|
|
| If the environment |
|
|
| ambient |
|
|
| temperature is |
|
|
| high, reduce the |
|
|
| ambient |
|
|
| temperature. |
|
|
| Make sure that the |
|
|
| airflow is not |
|
|
| blocked or |
|
|
| restricted on the |
|
|
| enclosure. |
|
|
|
|
Encl.xx Alarm zz is OFF | All conditions are normal or | No condition being | No action |
WWN: yy yy yy yy yy yy | the alarm is off. | reported. | necessary. |
|
| Alarm silenced. | User pressed the |
|
|
| Alarm Silence |
|
|
| button on the front |
|
|
| panel. |
|
|
|
|
Encl.xx Alarm zz is ON | Alarm is on. | A condition | Press the Alarm |
WWN: yy yy yy yy yy yy |
| caused the alarm | Silence button on |
|
| to sound. | the front panel and |
|
|
| isolate the cause |
|
|
| of the alarm. |
|
|
|
|
194 | www.gateway.com |