Chapter 9: Event Logs

Drive Event Messages

Description

Cause

Action

 

 

 

 

Drive CC Failure

The drive listed has failed

Typically because

Replace the hard

SN:xx xx xx xx xx xx A:yy

because of an

of a

drive.

D:zz

unrecoverable error. The

non-recoverable

 

 

meaning of each field is as

media error or

 

 

follows:

hardware error.

 

 

SN: Serial Number

 

 

 

A:

Array number

 

 

 

D: Drive number in array

 

 

 

 

 

 

Drive Inserted

The drive indicated has been

Drive was

No action

SN:xx xx xx xx xx xx xx

inserted. The meaning of

inserted.

necessary.

ID;yyy

each field is as follows:

 

 

 

SN: Drive World Wide Name

 

 

 

ID: Drive hard ID

 

 

 

 

 

 

Drive Invalid Block Size

This indicates that the

The drive has an

Replace the hard

(Size) SN:xx xx xx xx xx xx

specified drive has an invalid

invalid block size.

drive.

Py

block size, and so cannot be

 

 

 

used. A low level format is

 

 

 

required. The meaning of

 

 

 

each field is as follows:

 

 

 

SN: Serial Number

 

 

 

P:

Drive port number

 

 

 

Size: Current block size (in

 

 

 

hexadecimal). The

 

 

 

controller requires 512

 

 

 

Bytes.

 

 

 

 

 

 

Drive Missing

The drive listed has been

Drive has been

Replace the hard

SN:xx xx xx xx xx xx A:yy

marked as failed because of

removed or

drive.

D:z

being removed from the hard

bypassed by the

Replace the

 

drive enclosure. The

user, or has a

 

cables.

 

meaning of each field is as

serious hardware

 

Restore power to

 

follows:

error.

 

the daisy-chained

 

SN: Serial Number

Removal of cables

 

enclosure(s).

 

 

 

connecting the

 

A:

Array number

 

 

 

 

D: Drive number in array

enclosures.

Removal of power to daisy-chained enclosure(s).

186