Enclosure events

 

 

 

 

 

SES Event Messages

Description

Cause

Action

 

 

 

 

 

Encl.yy Temp. zz <aa>C

The controller has detected

Temperature

Automatic system

Warning WWN: xx xx xx xx

that the indicated

sensors are

shutdown will

xx xx xx xx

temperature sensor has

reporting

begin.

 

reached a warning limit.

enclosure

 

 

 

 

temperatureshave

 

 

 

 

reached the

 

 

 

 

threshold of 70°C.

 

 

 

 

 

 

 

 

 

 

Make sure that

 

 

 

both cooling fans

 

 

 

are operating

 

 

 

normally. (Replace

 

 

 

if needed.)

 

 

 

If the fans are set

 

 

 

to automatic

 

 

 

speed control,

 

 

 

place the jumper

 

 

 

on the Cooling fan

 

 

 

module circuit

 

 

 

board to force the

 

 

 

fans to high speed.

 

 

 

If the environment

 

 

 

ambient

 

 

 

temperature is

 

 

 

high, reduce the

 

 

 

ambient

 

 

 

temperature.

 

 

 

Make sure that the

 

 

 

airflow is not

 

 

 

blocked or

 

 

 

restricted on the

 

 

 

enclosure.

 

 

 

 

 